6.11.2
Types of info codes
Info code
Description Response
time
0 No
irregularities
-
1
Supply voltage has been cut off
-
8
Temperature sensor T1 outside measuring range
1…10 min.
4
Temperature sensor T2 outside measuring range
1…10 min.
32
Temperature sensor T3 outside measuring range
1…10 min.
64
Leak in the cold-water system
1 day
256
Leak in the heating system
1 day
512
Burst in the heating system
120 s
ULTRAFLOW
®
X4 info (if activated CCC=4XX)
16
Flow sensor V1, Datacomm error
After 1 day (00:00)
1024
Flow sensor V2, Datacomm error
After 1 day (00:00)
2048
Flow sensor V1, Wrong p
ulse
figure
After 1 day (00:00)
128
Flow sensor V2, Wrong p
ulse
figure
After 1 day (00:00)
4096
Flow sensor V1, Signal too low (Air)
After 1 day (00:00)
8192
Flow sensor V2, Signal too low (Air)
After 1 day (00:00)
16384
Flow sensor V1, Wrong flow direction
After 1 day (00:00)
32768
Flow sensor V2, Wrong flow direction
After 1 day (00:00)
Info code 1 will be logged when the mains supply/main battery is switched OFF and Info code 1 will be deleted
when the mains supply/main battery is switched ON. Thereby the time without power can be retrieved from the
logger data.
If several info codes appear at the same time the sum of the info codes is shown. E.g. if both temperature sensors
are outside measuring range, info code 12 will appear.
During configuration at the factory the individual info - active or passive - are set and in this way a standard heat
meter not using T3, cannot display info code 32.
Info = 16-1024-2048-128-4096-8192-16384-32768 functions via data communication between MULTICAL
®
and
ULTRAFLOW
®
54. See paragraph 13.2.4, Info code setup, in order to change the settings.
Important:
Forced info code update for ULTRAFLOW
®
X4 info codes
I
n certain cas
e
s, e.g. after installation of a meter, a shorter response time may be required for the ULTRAFLOW® X4
info codes than stated in the table above. These info codes are only available
if
CCC=4xx
ha
s
been
selected. In
order to perform a forced info code update, press the main key until the info code panel is displayed. After 10-20
seconds the meter will update the display with the current info code. The display is then updated every ten seconds
until the display returns to the main reading (accumulated energy) after about 4 minutes. This procedure may not
be repeated more than 25 times per day.
6.11.3
Transport mode
When the meter leaves the factory it is in transport mode, and the info codes are only active on the display and not
in the data logger. This prevents both ”info event” to increment and the storage of non relevant data in the info
logger. When the meter has summed up the volume register for the first time after installation the info code is
automatically set at active.