EE=15 Outlet temperature tariff
When the current outlet temperature (T2) is higher than TL2 but lower than/equal to TL3, the energy is counted in
TA2 in parallel to the main register. If the current outlet temperature becomes higher than TL3, the energy is counted
in TA3 in parallel to the main register.
T2
≤
TL2
Counting in main register only
TL3
TL2
TL3
T2
TL2
Counting in TA2 and the main register
T2
TL3
Counting in TA3 and the main register
When setting up data TL3 must always be higher than TL2.
The outlet temperature tariff can form the basis of a weighted user payment. A high outlet temperature indicates
insufficient heat utilization which is uneconomical for e.g. the heat supplier.
EE=19 Time-controlled tariff
The time-controlled tariff is used for time division of the heat consumption. If TL2 = 08:00 and TL3 = 16:00 the
consumption of the entire day from 08:00 till 16:00 will be accumulated in TA2, whereas the consumption of the
evening and the night from 16:01 till 07:59 will be accumulated in TA3.
TL2 must have a lower number of hours than TL3.
TL 3
Clock
TL2
Counting in TA2 and the main register
TL3
TL2
TL 2
Clock
TL3
Counting in TA3 and the main register
Among other things the time tariff is suitable for billing in housing sectors close to industrial sectors with a large
consumption of district heating and for billing industrial customers.
EE=20 Heat/cooling volume tariff
The heat/cooling volume tariff is used for dividing volume into heat and cooling consumption. TA2 accumulates
the volume consumed together with E1 (heat energy) and TA3 accumulates the volume consumed together with E3
(cooling energy).
T1
T2
Volume is accumulated in TA2 and V1
TL2 and TL3 are
not used
T2
T1
Volume is accumulated in TA3 and V1
In connection with combined heat/cooling measurement the total volume in the V1 register is accumulated,
whereas the heat energy is accumulated in E1 and the cooling energy in E3. The heat/cooling tariff divides the
consumed volume into heating and cooling volume.
EE=20 should always be selected together with combined heat/cooling meters, type 602-xxxxxxxx-6xx.