6.8.2
Average temperatures
MULTICAL
602 constantly calculates the average temperatures for inlet and outlet (T1 and T2) in the entire
C range
and the background calculations E8 and E9 (m
3
x T1 and m
3
x T2) are made for each energy calculation (e.g. for each
0.01 m
3
for qp 1.5 meter size), whereas the display value is updated every day. Thereby the average calculations
are weighted according to volume and can therefore be used for control purposes.
Registration type:
Average
Yearly data
Monthly data
Year-to-date average (since last target date)
Month-to-date average (since last target date)
Year-to-date average for T1.
(Current date with ”comma lines” under year or
month is shown just BEFORE this reading)
6.8.3
Programmed temperatures
The temperatures T3 and T4 can be programmed in the memory of the calculator, and these temperatures can be
used for calculating energy with fixed temperature reference, as used in connection with the calculations of the
energy types E4, E5, E6 and E7 (see the application drawings in paragraph 6.2)
The temperatures can be programmed when placing orders or by means of METERTOOL in the range 0.01…180
C,
once the meter is installed.