MULTICAL®
602
Kamstrup
A/S
∙
Technical
Description
∙
5512
‐
931_N1_GB_11.2016
23
3.4.1
Energy overview
Above energy types E1 to E9 are calculated as follows:
Formula
Example of an application
Included in Application No.
(see paragraph 6.2)
Register type
E1=V1(T1-T2)k
T1: Inlet / T2: Outlet
T1
>
T2
Heat energy (V1 in inlet or outlet pipe)
1+2+3+4+5+6+8+10
Legal
Display/Data/Log
E2=V2(T1-T2)k
T2: Outlet
T1
>
T2
Heat energy (V2 in outlet pipe)
2+7
Display/Data/Log
E3=V1(T2-T1)k
T2: Inlet / T1: Outlet
T2
>
T1
Cooling energy (V1 in inlet or outlet pipe)
1+11
Legal
Display/Data/Log
E4=V1(T1-T3)k
T1: Inlet
T1
>
T3
Inlet energy
7+9+11
Display/Data/Log
E5=V2(T2-T3)k
T2: Inlet
T2
>
T3
Outlet energy or tap from outlet pipe
5+7+9
Display/Data/Log
E6=V2(T3-T4)k
T3: Inlet
T3
>
T4
Tap water energy, separate
3+6
Display/Data/Log
E7=V2(T1-T3)k
T3: Outlet
T1
>
T3
Outlet energy or tap from inlet pipe
4+8
Display/Data/Log
E8=m
3
x T1
-
Average temperature in inlet pipe
See paragraph 6.2.2
Display/Data/Log
E9=m
3
x T2
-
Average temperature in outlet pipe
Display/Data/Log
3.5
>EE< Configuration of MULTITARIFF
MULTICAL
®
602 has 2 extra registers, TA2 and TA3, that accumulates energy E1 or E3 (EE=20 accumulates volume)
in parallel with the main register based on the limits programmed to tariff limits TL2 and TL3.
Example: EE=11 (power tariff)
TA2 shows the energy consumed …
… above the power limit TL2 (but below TL3)
T2
T3