Battery lifetimes
Supply options and battery lifetime for wall mounted MULTICAL
602 with ULTRAFLOW
54.
Estimated battery lifetime in years.
Top
Base
67-00
Without Top
module
67-02
E
67-09
V
67-03
PQ
67-07
M-Bus
67-05
Data
67-0A
2 pulse out +
scheduler
67-0B
2 pulse out +
prog.
datalogger
602-0C
2 pulse out
67-00-00
Without base module
12+1 12+1
Mains
only
12+1 10
9
10
67-00-10
Data+ pulse inp.
Monthly: 12
daily: 12
hourly: 10
min.: 5
Monthly: 12
daily: 12
hourly: 10
min.: 5
Mains
only
Monthly: 12
daily: 12
hourly: 10
min.: 5
Monthly: 10
daily: 9
hourly: 8
min.: 5
Monthly: 9
daily: 8
hourly: 7
min.: 4
Monthly: 10
daily: 9
hourly: 8
min.: 5
67-00-20/27/28/29
M-Bus+ pulse inp.
Monthly: 12
daily: 11
hourly: 9
min.: 1
Monthly: 12
daily: 11
hourly: 9
min.: 1
Mains
only
Monthly: 12
daily: 11
hourly: 9
min.: 1
Monthly: 10
daily: 9
hourly: 7
min.: 1
Monthly: 9
daily: 8
hourly: 6
min.: 1
Monthly: 10
daily: 9
hourly: 7
min.: 1
67-00-21
Radio Router
+pulse inp.
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
67-00-22
Prog. data analog inputs
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
67-00-23
0/4-20 Analogue Out
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
67-00-24
LONWorks
+pulse inp.
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
67-00-25/26
RF+p/i, read by
Hand Held Terminal
Monthly: 10
daily: 9
hourly: -
min.: -
Monthly: 9
daily: 8
hourly: -
min.: -
Mains
only
Monthly: 9
daily: 8
hourly: -
min.: -
Monthly: 8
daily: 7
hourly: -
min.: -
Monthly: 7
daily: 6
hourly: -
min.: -
Monthly: 8
daily: 7
hourly: -
min.: -
67-00-30/31/35/38/39
wM-Bus, Mode C1+pulse inp.
wM-Bus, Mode T1 OMS 15 min.
wM-Bus, Mode C1 Alt.reg.+pulse inp.
wM-Bus, Mode T1 OMS 16 s
wM-Bus, ModeC1 Fixed Network
12+1 12+1
Mains
only
12+1 10
9
10
602-00-36
wM-Bus, Mode T1 OMS 16 s
11
11
Mains
only
11
7
6
7
67-00-60
pulse inp.
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
67-00-62
Metasys N2
+pulse inp.
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
602-00-64
SIOX
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
67-00-66
BACnet MS/TP + pulse inputs
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
602-00-067
Modbus RTU +
pulse inputs
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
Mains
only
602-00-80
GSM/GPRS
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
602-00-81
3G GSM/GPRS modul (GSM8H)
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
602-00-84
High Power RF + pulse inp.
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
HP Mains
only
Note 1:
Battery lifetime in
years
at one data reading per month, day, hour or minute.
Note 2:
Battery temperature between 30 and 45
C (pipe mounted calculator) will reduce the lifetime by 1-3 years.
Note 3:
Connection of 2 ULTRAFLOW
will reduce the lifetime by 3 years.
Note 4:
With top module 67-0B, log intervals from 60 to 1 min. will reduce the battery lifetime by up to 3 years.
Note 5:
Connecting ULTRAFLOW
65 instead of ULTRAFLOW
54 will reduce the lifetime by 3 years.
Note 6:
Pulse outputs are calculated at an average of 50 % qp for standard CCC-codes and 32 ms. pulse duration.