MULTICAL®
602
Kamstrup
A/S
∙
Technical
Description
∙
5512
‐
931_N1_GB_11.2016
19
3.3.9
CCC codes for vane wheel meters with an electronic pick-up unit
Number of decimals on the display
CCC
no.
Pre-
counter
Flow
factor
kWh
MWh
Gcal
GJ
m³
ton
l/h
m³/h
kW
MW
Pulses/l
qp
m³/h
Type
Flow
sensor
102 560 421296
0 3 2 2 0 - 1 - 56.0
1.5/2.5 GWF-MT3 K
103 300 786420
0 3 2 2 0 - 1 - 30.0
3.5
GWF-MT3 K
104 2520 936214 - 2 1 1 0 - 1 - 25.2
6
GWF-MT3
K
105 1230 1918098 - 2 1 1 0 - 1 - 12.3
10
GWF-MT3
K
106 1080 2184500 - 2 1 1 0 - 1 - 10.8
15
GWF-MT3
K
108 1403 168158 0 3 2 2 0 - 1 - 140.3
0.6
GWF
K
109 957 246527
0 3 2 2 0 - 1 - 95.7 1.0
GWF
K
110 646 365211
0 3 2 2 0 - 1 - 64.6 1.5
GWF
K
111
404
583975
0
3
2
2
0
-
1
-
40.4
1.5 (2.5)
HM (GWF)
K
112
502
469972
0
3
2
2
0
-
1
-
50.2
1.5 – 2.5*
GWF
K
113
2350
1003940
-
2
1
1
0
-
1
-
23.5
3.5 - 6*
GWF
K
114
712
331357
-
2
1
1
0
-
1
-
7.12
10 - 15*
GWF
K
115
757
311659
0
3
2
2
0
-
1
-
75.7
1.0*
GWF
K
116
3000
78642
0
3
2
2
0
-
1
-
300.0
0.6*
GWF
K
117 269 877048
0 3 2 2 0 - 1 -
26.9
1.5
Brunata
K
118 665 354776
0 3 2 2 0 - 1 -
66.5
1.5
Aquastar K
119 1000 235926 0 3 2 2 0 - 1 - 100.0
0.6
HM
K
121
294
802469
0
3
2
2
0
-
1
-
29.4
1.5 – 2.5
K
122 1668 141442 0 3 2 2 0 - 1 - 166.8
0.6
HM
K
123
864
273063
0
3
2
2
0
-
1
-
86.4
0.75 - 1*
HM
K
124
522
451966
0
3
2
2
0
-
1
-
52,2
2.5 (1.5*)
CG (HM)
K
125
607
388675
0
3
2
2
0
-
1
-
60.7
1.5 - 1*
1.5*
HM K
126
420
561729
0
3
2
2
0
-
1
-
42.0
1.0 (2.5*)
CG (HM)
K
127 2982 791167 - 2 1 1 0 - 1 - 29.82
2.5
3.5*
HM K
128 2424 973292 - 2 1 1 0 - 1 - 24.24
3.5*
HM
K
129 1854 1272524 - 2 1 1 0 - 1 - 18.54
6*
HM
K
130 770
3063974
- 2 1 1 0 - 1 -
7.7
10*
HM
K
131 700
3370371
- 2 1 1 0 - 1 -
7.0
15*
HM
K
132 365 645665
0 3 2 2 0 - 1 -
36.54
2.5
Wehrle
K
133 604 390154
0 3 2 2 0 - 1 -
60.47
1.5
Wehrle
K
134 1230 191732 0 3 2 2 0 - 1 - 123.05
0.6
Wehrle
K
135 1600 1474538 - 2 1 1 0 - 1 - 16.0
10*
HM
K
139
256
921586
0
3
2
2
0
-
1
-
25.6
1.5 – 2.5
GWF
K
140
1280
1843172
-
2
1
1
0
-
1
-
12.8
3.5 – 5.0
GWF
K
141 1140 2069526 - 2 1 1 0 - 1 - 11.4
6
GWF
K
142 400 589815
- 2 1 1 - 2 - 3 4
10
GWF
K
143 320 737269
- 2 1 1 - 2 - 3
3.2
10
-
15 GWF
K
144
1280
1843172
-
1
0
0
-
2
-
3
1.28
25 - 40
GWF
K
145 640
3686344
- 1 0 0 - 2 - 3
0.64
60
GWF
K
146 128
18431719
- 1 0 0 - 2 - 3
0.128
125
GWF
K
152 1194 1975930 - 2 1 1 0 - 1 - 11.94
10
GWF
K
153 1014 2326686 - 2 1 1 0 - 1 - 10.14
15
GWF
K
156 594 397182
0 3 2 2 0 - 1 -
59.4
1.5
Metron
K
157 3764 626796 - 2 1 1 0 - 1 - 37.64
2.5
Metron
K
163
1224
192750
0
3
2
2
0
-
1
-
122.4
0.6 – 1.0
GWF/U2
K
164 852 280064
0 3 2 2 0 - 1 -
85.24
1.5
GWF/U2
K
165 599 393735
0 3 2 2 0 - 1 -
59.92
2.5
GWF/U2
K
168 449
5259161
- 2 1 1 0 - 1 -
4.486
15/25 HM/WS
K
169 1386 1702208 - 1 0 0 - 2 0 - 1.386
40
HM/WS
K
173 500 471852
- 1 0 0 - 1 - 2
0.5
80
Westland K
Current flow reading (l/h or m³/h) is calculated on the basis of volume pulses/10 s (see paragraph 6.5)
* Multiple-jet water meter