12.2
High-resolution volume for test
Should high-resolution reading of volume (V1HighRes) be required for test or verification it can be initialised as
follows:
-
Lift the calculator top off the connection base and wait for the display to turn off.
-
Press the sub-button
and re-mount the calculator top keeping the button pressed for approx. 8 seconds
until the display becomes active in HighRes mode.
-
The display remains active in HighRes verification mode until one of the push buttons is activated, or the
calculator top is reset.
Example:
V1 V1HighRes
0.001 m3
0.0001 L
0.01 m3
0.001 L
0.1 m3
0.01 L
1 m3
0.1 L
Example of a high-resolution volume (V1HighRes) reading:
The example below starts at a display value of 573.24 m
3
(v1). Having activated HighRes mode the display changes
to a high resolution and reading in litres appears. Subsequently, a pulse value for Verification can be added, in this
example 20.205.
00573.24 m
3
(0057)3.240000 m
3
3240.000 L
+ 20.205 L
3260.205 L
Note:
-
V1HighRes is periodically updated every 10 seconds.
12.2.1
Data reading of high-resolution Volume
The register ”HighRes” can be data read via ID = 239.
Data reading provides correct measuring unit and measuring value irrespective of meter size.