6.3
Calculator with two flow sensors
MULTICAL
602 can be used in various applications with two flow sensors, e.g. leak surveillance or open systems.
When two ULTRAFLOW
are direct connected to one MULTICAL
602, a close electric coupling between the two
pipes ought to be carried out as a main rule. If the two pipes are installed in a heat exchanger, close to the flow
sensors, however, the heat exchanger will provide the necessary electric coupling.
Electric coupling
Inlet and outlet pipes are closely electrically coupled
No welded joints occur
In installations where the electric coupling cannot be carried out, or where welding in the pipe system
can occur, the cable from one ULTRAFLOW
must be routed through a Pulse Transmitter with galvanic separation
before the cable enters MULTICAL
602.
Inlet and outlet pipes are not necessarily closely coupled
Electric welding
*)
can occur
*)
Electric welding must always be carried out with the earth pole closest to the welding point. Damage to meters
due to welding is
not
comprised by our factory warranty.