MAX. POWER V1
Value for max. power in the period
-
-
-
DATE FOR MIN. POWER V1
Date stamp for min. power in the period
-
-
-
MIN. POWER V1
Value for min. power in the period
-
-
-
T1avg
Time based average for T1
- -
-
T2avg
Time based average for T2
- -
-
T3avg
Time based average for T3
- -
-
P1avg
Time based average for P1
- -
-
P2avg
Time based average for P2
- -
-
Operating hour counter
Accumulated number of operating hours
- -
T1
Current value of T1
- -
- -
T2
Current value of T2
- -
- -
T3
Current value of T3
- -
- -
T4
Current value of T4
- -
- -
T1-T2 (
t)
Current differential value
- -
- -
Flow (V1)
Current water flow of V1
- -
- -
Flow (V2)
Current water flow of V2
- -
- -
Power (V1)
Actual power
- -
- -
P1
Current pressure of inlet
- -
- -
P2
Current pressure of outlet
- -
- -
Note
:
Continuous maximum
water flow
and
permanent
>
75 K
may cause overflow
in the daily
data logger
at
CCC=010-011-012-013-150-202-205.
With these combinations
we recommend you to use
Prog. data logger type
67-0B
or type 67-00-22.
6.13.2
Info logger
Every time the information code is changed, date and info code are logged. Thereby, it is possible to data read the
last 50 changes in the information code and the date of the change.
Register type
Description
Date (YY.MM.DD)
Year, month and day for the logging time
Info
Information code on above date
E1 Heat
energy
E3 Cooling
energy
Clock (hh.mm.ss.)
Time
When the info logger is read on the display the last 36 changes including dates can be read. Heat energy, cooling
Energy, and time can be read out via LogView only. Please see 6.11 for more information.