MULTICAL®
602
Kamstrup
A/S
∙
Technical
Description
∙
5512
‐
931_N1_GB_11.2016
65
6.18
Reset via the front keys
Via the the main key
and the sub-key
on MULTICAL
®
602, a number of reset functions can be made.
6.18.1
Activate the reset-menu
The reset-menu is activated in the following way:
1)
Select the display reading that you wish to reset
2)
Remove the calculator from the base
3)
Wait until the display goes blank (up to 2.5 minutes). Meanwhile do not touch the front keys
4)
While replacing the calculator on the base, press and hold the main key for approx. 8 seconds
5)
The reset-menu has now been activated
Having activated the reset menu, either the operation hour counter, the infoevent-counter or the error hour counter
will be displayed, depending on the register which was selected before activating the reset menu.
When the reset menu has been activated,”0” will be displayed. It is not possible to change to any other value. It is
only possible to “save” the value = 0 in order to reset the register, or to leave the reset menu without reset.
If a display register that is not supported by the reset-menu is selected, the meter will show the normal display
without activating the reset menu.
6.18.2
Exit the reset menu
When the operation hour counter, the info-event counter or the error hour counter displayes “0”, hold the main key
for 5-6 seconds, until the ”OK” segment is displayed, and the display reverts to legal reading.
If you wish to exit the reset menu without resetting any registers:
4)
Remove the calculator from the base
5)
Wait until the display goes blank (up to 2.5 minutes). Meanwhile do not touch the front keys
6)
Replace the calculator on the base without pressing the front keys
Allow some seconds for the meter to boot-up without pressing the front keys. The normal display register is now
displayed and the reset menu is deactivated.
Note that if the front keys are not activated for 4 minutes in the setup-menu, the setup-menu will be deactivated
and the meter will automatically return to normal operation.
No data will be reset in the meter’s memory, unless the “OK” segment is shown.
6.18.3
Display registers supported by the reset menu
The following registers are supported by the reset menu:
Operating hour counter
Error hour counter
Info event counter