Use the
no
version to delete a path.
■
See path ds3 t1.
path ds3 t1 clock source
■
Use to configure the transmit clock source for the T3 line.
■
Use a transmit clock recovered from the line’s receive data stream, except in
rare cases such as back-to-back router tests. When performing back-to-back
router tests, configure one end of the line as
internal
and the other end as
line
.
■
Specify the keyword
line
to use a transmit clock recovered from the line’s receive
data stream.
■
Specify the keywords
internal module
to use the line module’s internal clock.
■
Specify the keywords
internal chassis
to use the router’s clock.
■
On a cOC3/STM1 I/O module, you can configure some ports with internal clock
sources and others with line clock sources. However, all ports with internal clock
sources must use either the router’s clock or the module’s clock. You cannot
configure some ports on the I/O module to use the router’s clock and others to
use the module’s clock.
■
To change the clock source of the ports on a cOC3/STM1 I/O module from the
router’s clock to the module’s clock or vice versa, change the clock source of all
ports first to the line setting, and then to the new internal clock setting.
■
Example
host1(config-controll)#
path 12 ds3 1 t1 28 clock source internal chassis
■
Use the
no
version to restore the default value, line clocking.
■
See path ds3 t1 clock source.
path ds3 t1 description
■
Use to assign a text description or an alias to a T1 or fractional T1 channel on a
T3 (DS3) over channelized SONET/SDH interface.
■
You can use this command to help you identify the interface and keep track of
interface connections.
■
The description or alias can be a maximum of 80 characters.
■
Use “show controllers sonet ds3” on page 161 to display the text description.
■
Examples
host1(config-controller)#
path 12 ds3 1 t1 28 description boston_t1_on_t3
host1(config-controller)#
path 12 ds3 1 t1 28/5
description washington_fractional_t1_on_t3
■
Use the
no
version to remove the text description or alias.
■
See path ds3 t1 description.
path ds3 t1 framing
Configuration Tasks
■
135
Chapter 4: Configuring Channelized OCx/STMx Interfaces
Summary of Contents for JUNOSE 10.0.X PHYSICAL LAYER
Page 6: ...vi...
Page 8: ...viii JUNOSe 10 0 x Physical Layer Configuration Guide...
Page 16: ...xvi List of Figures JUNOSe 10 0 x Physical Layer Configuration Guide...
Page 18: ...xviii List of Tables JUNOSe 10 0 x Physical Layer Configuration Guide...
Page 28: ...2 Chapters JUNOSe 10 0 x Physical Layer Configuration Guide...
Page 98: ...72 Monitoring Interfaces JUNOSe 10 0 x Physical Layer Configuration Guide...
Page 200: ...174 Monitoring Interfaces JUNOSe 10 0 x Physical Layer Configuration Guide...
Page 253: ...Part 2 Index Index on page 229 Index 227...
Page 254: ...228 Index JUNOSe 10 0 x Physical Layer Configuration Guide...