182 Chapter 12: System Configuration
TempScan / MultiScan User's Manual
The
Trigger
and
Stop
can each be assigned any of the following sources:
•
@:
Trigger
and/or
Stop
event. Trigger source type
1
. When
@
is selected as the trigger source,
the
Trigger On
(
@
) command will generate a trigger.
•
GET:
Trigger
and/or
Stop
event. Trigger source type
2
. Not applicable for RS-232/RS-422 serial
applications. When GET is selected as the trigger source, data collection will start when the
IEEE 488 Group Execute Trigger (GET) command is sensed on the IEEE 488 bus and the
TempScan/1100 or MultiScan/1200 unit is addressed to LISTEN.
•
TALK:
Trigger
and/or
Stop
event. Trigger source type
3
. Not applicable for RS-232/RS-422
serial applications. When TALK is selected as the trigger source, data collection will start when
the TempScan/1100 or MultiScan/1200 unit is addressed to TALK.
•
Selected Temperature-Channel Level (Above or Below):
Trigger
and/or
Stop
event. Trigger
source types
4
and
5
. When a selected temperature channel is specified as the trigger source, data
collection will start when the level for the selected channel has been crossed (either above or
below), as defined via the
Set Trigger Level
(
L
) command.
•
External TTL (Rising or Falling):
Trigger
and/or
Stop
event. Trigger source types
6
and
7
.
When the External TTL Level is specified as a trigger source, a TTL level signal to the rear-panel
BNC trigger connector will generate a trigger. The external trigger is edge sensitive, and
triggering on the rising edge or falling edge can be specified.
•
Count (Post-Trigger):
Trigger
and/or
Stop
event. Trigger source type
8
. When Count is selected
as the
Stop
event, scans will occur until the specified number of
Post-Trigger
scans have been
acquired, as defined via the
Set Counts
(
Y
) command. At this point, the
Post-Trigger
acquisition
will stop and if configured, the
Post-Stop
acquisition will begin.
•
Alarm (On or Off):
Trigger
and/or
Stop
event. Trigger source types
9
and
10
. When Alarm is
selected as a trigger source, the acquisition will start or stop when any channel goes into or out of
an alarm condition, as defined via the
Configure Channels
(
C
) command.
•
Absolute Time:
Trigger
and/or
Stop
event. Trigger source type
11
. When absolute time is
specified as a trigger source, data collection will start when the real-time clock time equals the
programmed time(s), as defined via the
Program Trigger Times
(
P
) command.
Note:
For the MultiScan/1200 unit to recognize a
Trigger
(trigger start event) source which is set to
TTL Level or Alarm, at least one
Pre-Trigger
scan must be programmed via the
pre
parameter of the
Set Counts
(
Y
) command, to initiate scanning.
For more information on
Trigger
and
Stop
configuration, see command
Set Trigger Configuration
(
T
)
in the chapter
API Command Reference
.
Additional Configuration
Beyond the minimum required configurations, the TempScan/1100 or MultiScan/1200 provides further
convenience and flexibility with the following optional configurations:
•
Configuration of the alarms.
See commands
Assign Digital Alarm Output
(
A
) and
Channel
Configuration
(
C
).
•
Configuration of the stamps.
See commands
Set Scan Time Stamping
(
*T
),
Set Scan Alarm
Stamping
(
A#
), and
Set Digital Input Stamping
(
I#
).
•
Configuration of the data format.
See command
Set Data Format
(
F
).
•
Configuration of the power-up.
See command
Set Power-Up Configuration
(
*S
).
Summary of Contents for MultiScan 1200
Page 2: ...TempScan MultiScan User s Manual...
Page 4: ...TempScan MultiScan User s Manual...
Page 10: ...vi TempScan MultiScan User s Manual Notes...
Page 20: ...10 Chapter 1 System Overview TempScan MultiScan User s Manual Notes...
Page 106: ...96 Chapter 8 ChartView ChartView Plus TempScan MultiScan User s Manual Notes...
Page 130: ...120 Chapter 9 TempView TempScan MultiScan User s Manual...
Page 150: ...140 Chapter 9 TempView TempScan MultiScan User s Manual Notes...
Page 166: ...156 Chapter 10 PostView TempScan MultiScan User s Manual Notes...
Page 234: ...224 Chapter 13 System Operation TempScan MultiScan User s Manual Notes...
Page 248: ...238 Chapter 14 System Calibration TempScan MultiScan User s Manual Notes...
Page 284: ...274 Chapter 15 Program Examples TempScan MultiScan User s Manual Notes...
Page 330: ...320 Chapter 16 API Command Reference TempScan MultiScan User s Manual...
Page 342: ...332 Chapter 16 API Command Reference TempScan MultiScan User s Manual...
Page 358: ...348 Appendix TempScan MultiScan User s Manual Notes...
Page 364: ...354 Index TempScan MultiScan User s Manual Notes...