GD310-UL series VFD
Function parameter
-100-
Function
code
Name
Description
Default
value
Modify
P12.02
Rated
frequency of
asynchronous
motor 2
0.01Hz
–P00.03
(the max frequency)
controlling performance, set
the P12.01
–P12.05
according to the name plate
of the asynchronous motor.
Goodrive310-UL series
VFDs provide the function of
parameter autotuning.
Correct parameter
autotuning comes from the
correct setting of the motor
name plate.
In order to ensure the
controlling performance,
please configure the motor
according to the standard
principles, if the gap
between the motor and the
standard one is huge, the
features of the VFD will
decrease.
Note
: reset the rated power
of the motor (P12.01),
initialize the motor
parameter of
P12.02
–P12.05
60.00Hz
◎
P12.03
Rated speed
of
asynchronous
motor 2
1
–36000rpm
Depend
on model
◎
P12.04
Rated voltage
of
asynchronous
motor 2
0
–1200V
Depend
on model
◎
P12.05
Rated current
of
asynchronous
motor 2
0.8
–6000.0A
Depend
on model
◎
P12.06
Stator resistor
of
asynchronous
motor 2
0.001
–65.535Ω
After finish the motor
parameter autotuning, the
set value of P12.06
–P12.10
will renew automatically.
These parameters are basic
parameters controlled by
vectors which directly
impact the features.
Note
: Users cannot modify
the parameters freely.
Depend
on model
○
P12.07
Rotor resistor
of
asynchronous
motor 2
0.001
–65.535Ω
Depend
on model
○
P12.08
Leakage
inductance of
asynchronous
motor 2
0.1
–655.35mH
Depend
on model
○
P12.09
Mutual
inductance of
asynchronous
motor 2
0.1
–655.35mH
Depend
on model
○
Summary of Contents for GD310-011P-4-UL
Page 1: ......
Page 269: ...6 6 0 0 1 0 0 3 9 3 ...