GD310-UL series VFD
Function parameter
-88-
Function
code
Name
Description
Default
value
Modify
motor during braking can be converted into heat
energy by increasing the magnetic flux.
The VFD monitors the state of the motor
continuously even during the magnetic flux period.
So the magnetic flux can be used in the motor stop,
as well as to change the rotation speed of the motor.
Its other advantages are:
Brake immediately after the stop command. It does
not need to wait the magnetic flux weaken.
Better cooling for motors. The current of the stator
other than the rotor increases during magnetic flux
braking, while the cooling of the stator is more
effective than the rotor.
P08.51
Current
regulation
coefficient on
input side
This function code is used to adjust the displayed
current of the AC input side.
Setting range: 0.00
–1.00
0.56
○
P09 Group PID control
Function
code
Name
Description
Default
value
Modify
P09.00
PID reference
source
When the frequency command selection (P00.06,
P00. 07) is 7 or the voltage setting channel selection
(P04.27) is 6, the running mode of the VFD is
procedure PID controlled.
The parameter determines the target given channel
during the PID procures.
0: Set by P09.01
1: AI1
2: AI2
3: AI3
4: HDI
5: Multi-step speed set
6: MODBUS communication set
7: PROFIBUS/CANopen communication set
8: Ethernet communication set
9: Reserved
0
○