LED Functions
Video Output and Routing
Output Format
Proc Ch 1 and 2 Out Format
Use these controls to select the output video format for processing channel outputs. The
Proc Bypass
option bypasses the scalar and all processing (noise reduction, detail
enhancement, color correction, etc.) but is downstream of the frame synchronization. The
default is
Follow Ref
(external genlock source).
Table 3-2
LED Functions
LED
Name
Condition Indicated
System
Red:
X100 is powering up
Major fault has occurred, such as controller module failure, FPGA
failure, or submodule missing
Amber:
The X100 is powering up
A non-service fault is detected, such as a failed fan or power supply
Green: X100 is ready for operation
Off: The system is not powered
Inputs 1
and 2
Red: Loss of signal on active input
Amber: Errors are detected on an active input
Green: All inputs are error-free
Off: System LED is red
TSG
Red: Not applicable
Amber: Not applicable
Green: Test signal generator is operating
Off: Test signal generator is not enabled
Ref
Red: Genlock is enabled, but reference input is missing
Amber: Genlock is enabled, but reference is wrong standard
Green: Genlock is enabled and reference input is OK
Off: No Reference is enabled
Alarm
Red: Alarm condition
Amber: Not applicable
Green: Not applicable
Off: No Alarm function
Summary of Contents for Selenio X100
Page 8: ...Selenio X100 Installation and Operation Manual viii...
Page 21: ...Selenio X100 Installation and Operation Manual 9 Figure 1 5 X100 Signal Flow...
Page 22: ...Selenio X100 Installation and Operation Manual 10...
Page 38: ...Selenio X100 Installation 26...
Page 158: ...Appendix A Laser Safety Guidelines 146...
Page 178: ...166...