15
Changing Jumper Settings
There are several sets of jumpers on the X100:
LTC In/ Out (600
or Hi-Z)
Serial Port Rx/Tx Termination (RS-232, RS-422, RS-485)
Analog Audio In/Out (600
or Hi-Z)
All of these jumpers are accessible only after the removal of the top cover, as described on
page 148. Follow the markings on the board to set the pins of the jumpers. A white triangle
on the board indicates
Pin 1
. Ensure that you disconnect both power supplies before
opening the cover.
Figure 2-6.
LTC In/ Out Jumpers (600
or Hi-Z)
For serial port Rx/Tx termination (
), jumpers are required only when the module is
set to
RS-422
. As shown in the picture, two jumpers are required. When the module is set
to
RS-232
or
RS-485
, no jumpers are needed.
LTC Output
LTC Input