Selenio X100
Installation and Operation Manual
62
Data Output and Data Bridging
For each SDI output blanking line, you can select up to two kinds of data to be embedded
into the same line. Source data can be routed from the same processing channel input or
bridged from a different processing channel input. Source data can also be routed from the
audio metadata generator, serial-triggered data, or GPI-triggered data. (When two
conflicting data types are selected for the same line, the
Output Selection Status
displays
an error message.)
There are up to two data selections per line when selecting data to embed into an SDI
output. To adjust the number of visible embedding controls for a particular VBI line, set
Data Output > Proc Ch x Output >
Line to Edit
to the target line, then adjust the
Number of Data on Line x
parameter for that line.
For outputs other than SDI, you can select data for LTC, serial, or GPI output.
VBI Line Delete
For each SDI VBI line data embedding selection, you can select
VBI Line Delete
to remove
everything on that line. If the output standard is interlaced, a field selection parameter (
VBI
Delete Field LN x)
is enabled, which will
then allow you to select which field to apply the
VBI deletion to. Options for
VBI Delete Field LN x
are:
1st Field, 2nd Field,
and
Both
Fields (default)
.
Generic VANC Data Passing
Up to 10 different types of VANC data packets (specified by the DID/SDID) can be routed
from the SDI input to the SDI output. The system can also automatically identify the newly
detected DID/SDID, and fill the detected value into the first available empty DID/SDID
control.
When
Data Auto Pass
is set to
Yes
at
Advanced Data Status and Control >
General
, the output embedding will also automatically pass the newly discovered data into
the output.
VBI Transfer
The
VBI Transfer
parameter makes it possible to transfer all VBI/VANC data (excluding the
data in the HANC region) transparently from the input to the output. (
VBI Transfer
is only
available when the input and output video standards are the same.)
If the VBI transfer is disabled, you will need to manually configure the data embedder to
embed the VBI/VANC data you require at the output. This is because the X100 (except
when operating in
Proc Bypass
mode) strips out all VBI/VANC data from the
video when
performing video processing and scaling. The
VBI Transfer
control is located at
Data
Output > Proc Ch x Output.
Dual Link Support
If a dual link video standard is used, the
Link Selection
control
(
Advanced Data Status
and Control > General
) makes it possible to select which link sys
tem should be used when
de-embedding and embedding VANC data.
Summary of Contents for Selenio X100
Page 8: ...Selenio X100 Installation and Operation Manual viii...
Page 21: ...Selenio X100 Installation and Operation Manual 9 Figure 1 5 X100 Signal Flow...
Page 22: ...Selenio X100 Installation and Operation Manual 10...
Page 38: ...Selenio X100 Installation 26...
Page 158: ...Appendix A Laser Safety Guidelines 146...
Page 178: ...166...