Selenio X100
Installation and Operation Manual
56
Texture Level and Texture Overshoot
The
Texture Level
parameter is used in conjunction with the
Noise Reduction
control to
provide enhancement on small edges.
Texture Overshoot
is used in conjunction with the
Texture Level
to provide
enhancement on small edges.
Noise Adaptation
This parameter sets the noise adaptation threshold for sharpness and texture enhancement.
It controls the noise reduction setting in conjunction with the motion in the video signal, on
a scale of
0
to
1000
.
Film Mode Enable
Use this parameter to enable cadence detection and “film mode” video processing.
Logo Generation and Insertion
The Selenio X100 provides logo generation, static on-screen logo insertion, and animated
on-screen logo insertion.This feature requires an optional 8 GB or 16 GB memory module
(X100OPT-MEMMOD8GB or X100OPT-MEMMOD16GB, respectively); and an
X100OPT-SK-ALG software key license. For dual-channel logo generation and insertion, two
softkeys are required.
The memory module is shared with the X100’s program delay feature. Both the program
delay and the logo generator can be used at the same time. However, the 16 GB memory
makes it possible to use longer animated logos.
Static logos used by the X100 are in the
.mg2
file format. Starting from release 2.0, with
additional memory module installed, the X100 provides on-screen animated logo insertion
capability. Animated logos used by the X100 are stored in the VIA 2.0 file format with file
extension.
via
.
Logo files must be loaded into the X100 before they can be displayed. There are two
storage locations: the main board (up to 10MB), and the
optional memory module (16 GB).
Main board storage location is used to store files for static logo display only; the memory
module location stores both static and animated logos.
To load a logo file into the system, follow these steps:
1
On the
Configuration
page, select
Logo Management
.
2
Click the
Upload
button to select the file for previewing and uploading.
3
To upload file into the optional memory module, select the
MemoryModuleLogos
sub-directory.
4
Click
Upload
.
When a memory module and its accompanying license keys are installed, additional
animated logo related controls are then enabled.
Summary of Contents for Selenio X100
Page 8: ...Selenio X100 Installation and Operation Manual viii...
Page 21: ...Selenio X100 Installation and Operation Manual 9 Figure 1 5 X100 Signal Flow...
Page 22: ...Selenio X100 Installation and Operation Manual 10...
Page 38: ...Selenio X100 Installation 26...
Page 158: ...Appendix A Laser Safety Guidelines 146...
Page 178: ...166...