Selenio X100
Installation and Operation Manual
30
Output Routing
The
Output Routing
parameters assign the SDI outputs to their processing channels.
The
SDI x Out Select
parameters control which video channel is assigned to the four SDI
outputs. Options are
Processing Channel 1
(default)
Processing Channel 2, Processing
Channel 1 + OSD,
and
Processing Channel 2 + OSD
.
The same options are available using the
SFP x Out Select,
HDMI Out Select,
and
Analog
x Out Select
parameters.
Note
:
External video inputs and outputs can be disabled by the
Green (Power Save)
control located in the
Miscellaneous
section. If an external video control is grayed out in
the user interface, check its power save status.
Operation Mode
Dual Channel
In this mode, both channels are completely independent (however, both channels share the
same genlock reference).
Live I-Wings Mode
The
Live I-Wings
mode displays video or graphics on the two “wings” on either side of an
SDI signal located within a larger aspect ratio signal.
Figure 3-1 I-Wings Mode
Live I-Wings
integrated content insertion keys HD- or SD-SDI content into the sidebar
portion of the output image raster using the X100 internal keyer. The input to channel one,
is the main center image; the input to channel two provides the “wings”.This option is
useful, for example, in applications where upconversion of SD-SDI 4:3 content is being
performed, and insertion of additional content is required in the 16:9 upconverted image
raster's sidebars.
To set up the
Live I-Wings
feature, follow these steps:
1
Set the ARC parameters as required.
Live I-Wings will only appear in the background area. Therefore, ARC settings that are
anamorphic will block I-Wings from appearing.
2
Select
Live I-Wings
in the
Operation Mode
parameter
.
Scalar
Proc
Mux
Processing
Channel 1
Demux
Sync
Frame
sync
Frame
sync
Processing
Channel 2
Summary of Contents for Selenio X100
Page 8: ...Selenio X100 Installation and Operation Manual viii...
Page 21: ...Selenio X100 Installation and Operation Manual 9 Figure 1 5 X100 Signal Flow...
Page 22: ...Selenio X100 Installation and Operation Manual 10...
Page 38: ...Selenio X100 Installation 26...
Page 158: ...Appendix A Laser Safety Guidelines 146...
Page 178: ...166...