Selenio X100
Installation and Operation Manual
17
Configuring Network Settings
When shipped, the Selenio X100 is configured with a default IP address, subnet mask, and
default gateway. If you intend to control the unit remotely, or connect it to a network hub/
switch along with other Selenio X100 units, you will need to reconfigure the IP with unique
network settings. Local control (with a direct Ethernet crossover connection to a PC) does
not require any IP configuration.
Supported Network Protocols
The Selenio X100 supports the following network protocols for remote/network control:
CCS Protocol
HTTP
SNMP
Making Required Hardware Connections
If you are connecting an Selenio X100 directly to a PC (no network connection), connect
one end of a crossover Ethernet cable to the
Control
Ethernet
RJ-45 port on the back of
the frame, and the other end to the PC
Ethernet
port. If you are establishing a network
connection, connect a straight-through 10/100Base-T Ethernet cable between the Selenio
X100
Control
Ethernet
port and the network hub/switch.
Setting IP and Subnet Mask Addresses
To allow devices to communicate on a network, you need to set all Selenio X100 devices to
the same subnet (network location). When shipped, Selenio X100 units are configured with
the same default IP (device identifier) and subnet addresses. These addresses need to be
changed so that each unit is uniquely identified and the network location of all units is
accurately reflected. An IP address is made up of a four-item set of numbers (octet). The
default (factory-configured) IP address for every Selenio X100 unit is
192.168.100.250
. For
a class C network, you must change the first three items in the octet to identify the location
(address) of the unit on your network, and also change the last item in the octet to uniquely
identify the device from other Selenio X100 units.
The default subnet mask address for every Selenio X100 is
255.255.255.0
.
Setting the IP Address of a Single Unit with a Local or Remote
Control Panel
Follow these steps to configure the network addresses using a local or remote control
panel:
1
Follow this path:
System Config
>
Setup
(in the RCP, select
Device Setup
).
2
Scroll to the
Device IP
parameter, and then press
Enter
.
If this is a new unit being configured, the default IP displays. Otherwise, the current IP
address of the unit displays.
Summary of Contents for Selenio X100
Page 8: ...Selenio X100 Installation and Operation Manual viii...
Page 21: ...Selenio X100 Installation and Operation Manual 9 Figure 1 5 X100 Signal Flow...
Page 22: ...Selenio X100 Installation and Operation Manual 10...
Page 38: ...Selenio X100 Installation 26...
Page 158: ...Appendix A Laser Safety Guidelines 146...
Page 178: ...166...