Parameters of the outputs
7900
Parameter
Data type
Description
N_NODES
WORD
value = 0:
None of the nodes has a guarding or heartbeat error.
value
0:
number of nodes with heartbeat or guarding error
NODEID ARRAY
[0...MAXGUARDERROR] OF
BYTE
Starting from index 0 the node IDs with a heartbeat or guarding error
are entered. The most recent entry is in index 0.
MAXGUARDERROR depends on device
chapter
Performance limits of the devices (CANopen)
(
→
RESULT
BYTE
feedback of the function block
(possible messages
following table)
Possibly values for RESULT:
Value
dec | hex
Description
000
00
function block is not active
001
01
function block execution completed without error
008
08
FB is active – not yet processed
242
F2
Error: setting is not possible