CAN in the PDM360
CAN units acc. to SAE J1939
221
Parameters of the outputs
7674
Parameter
Data type
Description
SA
BYTE
current source address
(e.g. after address claiming)
CYCLIC
WORD
number of the cyclic messages
TIMEOUT
BYTE
source address of the node which did not provided data for the
process image in due time
255
10
= FF
16
= all nodes sent the data in due time
VERSION
DWORD
version of the CAN stack
RESULT
BYTE
feedback of the function block
(possible messages
following table)
Possibly values for RESULT:
Value
dec | hex
Description
000
00
function block is not active
001 01
Protocol
active
002 02
Protocol
inactive
003 03
Source
address
claimed
004 04
Address
lost
242
F2
Error: setting is not possible