![IFM PDM360NG Series System Manual Download Page 237](http://html1.mh-extra.com/html/ifm/pdm360ng-series/pdm360ng-series_system-manual_3875026237.webp)
ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN units acc. to SAE J1939
237
Parameters of the outputs
7735
Parameter
Data type
Description
SA BYTE
S
ource
a
ddress of the transmitter
PRIO
BYTE
message priority (0…7)
LEN
BYTE
number of the bytes received (0...8)
DATA
ARRAY [0...7] OF BYTE
received data, (1...8 bytes)
MORE_DATA_AVAILABLE BOOL
TRUE:
further
received data available in the FiFo
FALSE:
no further data available in the FiFo
RESULT
BYTE
feedback of the function block
(possible messages
following table)
Possibly values for RESULT:
Value
dec | hex
Description
000
00
function block is not active
001
01
FB execution completed without error – data is valid
005
05
FB is active – no data received yet
242
F2
Error: setting is not possible
250
FA
Error: FiFo is full – data was lost