![IFM PDM360NG Series System Manual Download Page 302](http://html1.mh-extra.com/html/ifm/pdm360ng-series/pdm360ng-series_system-manual_3875026302.webp)
ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN POUs to CANopen
302
Parameters of the outputs
7894
Parameter
Data type
Description
RXOVFL
BOOL
Condition of the RX overflow flag
TRUE:
Overflow in the receive buffer
FALSE:
No overflow in receive buffer
RXWARN
BOOL
Condition of the RX overflow warning flag
TRUE:
Level in the receive buffer is critical
FALSE:
Level in the receive buffer is uncritical
TXOVFL
BOOL
Condition of the TX overflow flag
TRUE:
Overflow in the transmit buffer
FALSE:
No overflow in transmit buffer
TXWARN
BOOL
Condition of the TX overflow warning flag
TRUE:
Level in the transmit buffer is critical
FALSE:
Level in the transmit buffer is uncritical
RESULT
BYTE
feedback of the function block
(possible messages
following table)
Possibly values for RESULT:
Value
dec | hex
Description
000
00
function block is not active
001
01
function block execution completed without error
008
08
function block not yet executed
242
F2
Error: setting is not possible