Parameters of the inputs
7667
Parameter
Data type
Description
ENABLE
BOOL
TRUE:
unit is executed
FALSE:
unit is not executed
> POU inputs and outputs are not active
CHANNEL
BYTE
CAN interface (1...n) depending on the device
IndustryGroup
(optional use of the parameter)
BYTE
industry group = industry group of the device
permissible values = 0...7
preset = 255
10
= FF
16
**)
VehicleSystemInstance
(optional use of the parameter)
BYTE
instance of the vehicle system
permissible values = 0...15
10
preset = 255
10
= FF
16
**)
VehicleSystem
(optional use of the parameter)
BYTE vehicle
system
permissible values = 0...127
10
preset = 255
10
= FF
16
**)
nFunction
(optional use of the parameter)
WORD
function of the device
permissible values = 0...255
10
preset = 65 535
10
= FFFF
16
**)
FunctionInstance
(optional use of the parameter)
BYTE
instance of the function
permissible values = 0...31
10
preset = 255
10
= FF
16
**)
ECUInstance
(optional use of the parameter)
BYTE
instance of the control device
permissible values = 0...7
preset = 255
10
= FF
16
**)
ManufacturerCode
(optional use of the parameter)
WORD
manufacturer code (must be requested from SAE)
permissible values = 0...2047
10
(2
11
-1)
preset = 65 535
10
= FFFF
16
**)
IdentityNumber
(optional use of the parameter)
DWORD
serial number of the device (should not be overwritten)
permissible values = 0...2047
10
(2
11
-1)
preset = 4 294 967 295
10
= FFFF FFFF
16
**)
**) The preset value is not taken into account in the request.