ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN POUs to CANopen
266
In addition to the prescribed entries, the EDS file contains the definitions for SYNC, guarding,
emergency and heartbeat. If these objects are not used, the values are set to 0 (preset). But as the
objects are present in the object directory of the slave at runtime, they are written to in the EDS file.
The same goes for the entries for the communication and mapping parameters. All 8 possible sub-
indices of the mapping objects 16xx
16
or 1Axx
16
are present, but possibly not considered in the sub-
index 0.
NOTE:
Bit mapping is not supported by the library!
Tab [Default PDO mapping]
1983
In this tab the assignment between local object directory (OD editor) and PDOs transmitted/received
by the CANopen slave can be defined. Such an assignment is called "mapping".
In the object directory entries used (variable OD) the connection to variables of the application is made
between object index/sub-index. You only have to ensure that the sub-index 0 of an index containing
more than one sub-index contains the information concerning the number of the sub-indices.