Parameters of the inputs
7652
Parameter
Data type
Description
CHANNEL
BYTE
CAN interface (1...n) depending on the device
ENABLE
BOOL
TRUE:
any address available
FALSE: fixed
address
IndustryGroup
(optional use of the parameter)
BYTE
industry group = industry group of the device
permissible values = 0...7
preset = 255
10
= FF
16
**)
VehicleSystemInstance
(optional use of the parameter)
BYTE
instance of the vehicle system
permissible values = 0...15
10
preset = 255
10
= FF
16
**)
VehicleSystem
(optional use of the parameter)
BYTE vehicle
system
permissible values = 0...127
10
preset = 255
10
= FF
16
**)
nFunction
(optional use of the parameter)
WORD
function of the device
permissible values = 0...255
10
preset = 65 535
10
= FFFF
16
**)
FunctionInstance
(optional use of the parameter)
BYTE
instance of the function
permissible values = 0...31
10
preset = 255
10
= FF
16
**)
ECUInstance
(optional use of the parameter)
BYTE
instance of the control device
permissible values = 0...7
preset = 255
10
= FF
16
**)
ManufacturerCode
(optional use of the parameter)
WORD
manufacturer code (must be requested from SAE)
permissible values = 0...2047
10
(2
11
-1)
preset = 65 535
10
= FFFF
16
**)
IdentityNumber
(optional use of the parameter)
DWORD
serial number of the device (should not be overwritten)
permissible values = 0...2047
10
(2
11
-1)
preset = 4 294 967 295
10
= FFFF FFFF
16
**)
**) The preset value is not overwritten.
Parameters of the outputs
7661
Parameter
Data type
Description
RESULT
BYTE
feedback of the function block
(possible messages
following table)
Possibly values for RESULT:
Value
dec | hex
Description
000
00
function block is not active
001
01
function block execution completed without error
008
08
function block is active
242
F2
Error: setting is not possible