PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN POUs to CANopen
250
CAN parameters: Write DCF
10037
If [Write DCF] is activated, a DCF file is created after adding an EDS file to the set directory for
compilation files. The name of the DCF file consists of the name of the EDS file and appended node
ID.
CAN parameters: Create all SDOs
10038
If this option is activated, SDOs are generated for all communication objects.
Default values are not written again!
CAN parameters: Node reset
10039
The slave is reset ("load") as soon as the configuration is loaded to the controller.
CAN parameters: Optional device
10040
If the option [optional device] is activated, the master tries only once to read from this node. In case of
a missing response, the node is ignored and the master goes to the normal operating state.
If the slave is connected to the network and detected at a later point in time, it is automatically started.
To do so, you must have selected the option [Automatic startup] in the CAN parameters of the master.
CAN parameters: No initialization
10041
If this option is activated, the master immediately takes the node into operation without transmitting
configuration SDOs. (Nevertheless, the SDO data is generated and stored in the controller.)
CAN parameters: Nodeguarding / heartbeat settings
10042
Depending on the device you can choose:
- [nodeguarding] and [life time factor] must be set OR
- [heartbeat] must be set.
We recommend: It is better to work with the heartbeat function for current devices since then the bus
load is lower.
CAN parameters: Emergency telegram
10043
This option is normally selected. The EMCY messages are transferred with the specified identifier.