ifm
System Manual
ecomat
mobile
PDM360NG (CR1080, CR1081, CR9042) Target V01
2011-07-28
CAN in the PDM360
CAN units acc. to SAE J1939
225
J1939_TX_ENH
7696
= J1939 TX enhanced
Unit type = function block (FB)
Contained in the library:
ifm_J1939_NT_Vxxyyzz.LIB
Available for the following devices:
- BasicController: CR040n
- BasicDisplay: CR0451
- PDM360NG: CR108n, CR9042
Symbol in CoDeSys:
Description
7697
Additional setting options are provided by J1939_TX_ENH (for: enhanced) for single frame messages:
transmitting
priority
data
length
Multi frame messages
J1939_TX_ENH_MULTI (
→
page
Parameters of the inputs
7702
Parameter
Data type
Description
ENABLE
BOOL
TRUE:
unit is executed
FALSE:
unit is not executed
> POU inputs and outputs are not active
CHANNEL
BYTE
CAN interface (1...n) depending on the device
DA BYTE
DA
=
D
estination
A
ddress
if PGN > 61139, parameter is ignored
preset = 249
10
= F9
16
Prio
(optional use of the parameter)
BYTE message
priority
permissible values = 0…7
preset = 6
PGN DWORD
PGN
=
P
arameter
G
roup
N
umber
permissible values = 0000 0000...0003 FFFF
16
(0...262 143
10
)
Len
(optional use of the parameter)
BYTE
number of the bytes to be transmitted
permissible values = 0...8
preset = 8
DATA
ARRAY [0...7] OF BYTE
data to be sent (1...8 bytes)