2011-07-28
CAN in the PDM360
CAN errors and error handling
324
Parameters of the outputs
7925
Parameter
Data type
Description
N_MSGS
DWORD
number of accumulated messages
highest index designates oldest message
EMCY ARRAY
[0...MAXEMCYMSGS]
OF T_EMCY
emergency messages
structure of T_EMCY:
.NODEID
ID of the node from which the message came
.EEC
Emergency error code
.ER
Error register
.MSEF
Manufacturer specific error code
MAXEMCYMSG = 10
RESULT
BYTE
feedback of the function block
(possible messages
following table)
Possibly values for RESULT:
Value
dec | hex
Description
000
00
function block is not active
001
01
function block execution completed without error
008
08
FB is active – not yet processed
242
F2
Error: setting is not possible