User Program Capacity
This section describes the function to select the user program capacity on the FC6A Series MICROSmart.
Function Description
If the default FC6A Series MICROSmart user program capacity is insufficient, you can secure a larger user program capacity.
However, Online Edit can no longer be used.
Programming WindLDR
You can set the user program capacity of the All-in-One CPU module and CAN J1939 All-in-One CPU module.
The Plus CPU module is fixed to 800,000 bytes.
1.
On the
Configuration
tab, in the
Function Area Settings
group, click
Device Settings
.
The
Function Area Settings
dialog box is displayed.
2.
For
Program Capacity Selection
, select 72,000 bytes, 384,000 bytes (All-in-One CPU module), or 640,000 bytes (CAN
J1939 All-in-One CPU module).
3.
Click
OK
.
This concludes configuring the settings.
CPU Module Type
User Program Capacity
Default Capacity
When Securing a Larger User Program Capacity
All-in-One CPU Module
72,000 bytes (9,000 steps)
384,000 bytes (48,000 steps)
CAN J1939 All-in-One
CPU Module
640,000 bytes (80,000 steps)
Plus CPU Module
800,000 bytes (100,000 steps)
Summary of Contents for MICROSmart FC6A Series
Page 1: ...B 1722 8 FC6A SERIES User s Manual...
Page 12: ...TABLE OF CONTENTS Preface 11 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Page 182: ...2 PRODUCT SPECIFICATIONS 2 152 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Page 434: ...8 INSTRUCTIONS REFERENCE 8 18 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Page 520: ...11 SD MEMORY CARD 11 54 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Page 554: ...13 TROUBLESHOOTING 13 26 FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722...
Page 567: ...FC6A SERIES MICROSMART USER S MANUAL FC9Y B1722 A 13 APPENDIX ASCII Character Code Table...