Table 4: FIDs and FRUs (continued)
Reporte
d FID
FRUs FRU name or description
Prob-
ability
Page reference or instruction
59
Decryption error - Error was detected during the decryption of data
83
Microcode
25%
“FID 84 or E6 - Isolating fault between
microcode and hardware” on page 240
-
Encryption Key Manager
25%
IBM External Key Manager Introduction, Planning,
and User's Guide
87
Tape cartridge
25%
“FID 87 or F2 - Isolating fault between media
85
Drive canister
25%
• “FID 85: Drive canister” on page 252
5A
Encryption Key Manager failure - An unexpected status was returned by the key manager. Check the
proxy interface and the Encryption Key Manager log.
Note: This issue is not a drive or microcode problem. The customer must isolate the problem from
this symptom.
5B
Encryption PROXY failure - A failure or timeout occurred on the proxy interface. Check the proxy
interface and the Encryption Key Manager log.
Note: This issue is not a drive or microcode problem. The customer must isolate the problem from
this symptom.
5F
Security prohibited function - A function was attempted which is prohibited.
81
Thermal sensor detected overtemperature condition
1. If you suspect that the problem is because of environmental conditions, you can order and use a
datalogger tool (P/N 45P5917) to record ambient temperature. Contact your next level of
support for procedures to correct this condition.
2. If the environmental conditions are within specification and the problem persists, replace the
drive canister.
85
Drive canister
100% • “FID 85: Drive canister” on page 252
82 or C1 Drive voltage not within specification, the drive detects a power outage, or a power supply-cooling
fan failed
Notes:
• This error can be triggered only when a tape is loaded in the drive.
• This error can take up to 50 minutes to be reported after the condition is detected.
82
Power supply
88% “Power problems MAP” on page 193
EA
Power supply cables
8%
• “FID EA: Cables FRU kit” on page 255
85
Drive canister
4%
• “FID 85: Drive canister” on page 252
83 or E5 Microcode fault
83
Microcode
100% “FID 83 or E5 - Microcode problem” on page 239
8 IBM 3592 TS1140, TS1150, TS1155, and TS1160 Tape Drives: Maintenance Information