11. Use your local procedures to report the FRU part number for the FID.
Call Reporting Note: After you install the drive, report the drive part number usage against the 3592
drive machine type and model, not against the library machine type and model.
FID EA: Cables FRU kit
Attention:
The Rack Mount Card (RMC) is ESD sensitive. See “Electrostatic discharge (ESD)
sensitive parts” on page 192 before ESD-sensitive parts are handled.
See Figure 79 on page 251 for FRU location EA. The cables FRU kit contains the rack mount card cable.
Removing the cables
Figure 1
DETAIL A
Screws
Hook-and-loop
fasteners
Drive cable
assembly
Ethernet
couplers
Ethernet
connector
Power
connector
a05m0379
Figure 83: Removing the top cover, showing the cable assembly
1. Complete “Preparing the tape drive for service” on page 183, then return here.
2. Complete “Removing the drive canister from an enclosure” on page 253, then return here.
3. Remove the enclosure from the rack. See “Removing the enclosure from a rack” on page 258.
4. Place the enclosure on a table or work area.
5. Remove four screws from the top cover (Figure 83 on page 255) and lift the cover from the enclosure.
6. Remove the hook-and-loop fasteners (2 for each cable).
7. Disconnect the Ethernet and power connector (Figure 83 on page 255, DETAIL A) and remove the
cable.
8. Remove the Ethernet coupler, if necessary.
Replacing the cables
1. Install the Ethernet coupler, if necessary. See Figure 83 on page 255
2. Install the two ferrite beads on the cable assembly, if necessary. See Figure 84 on page 256.
Locations, checks, adjustments, removals, and replacements 255