Chapter 8. Locations, checks, adjustments, removals,
and replacements
These topics provide reference and procedural information for Field Replaceable Units (FRUs).
Rack FRU locations, removals, and replacements
The FRUs in Figure 79 on page 251 are identified by their FID number. For example, 82 is FID 82, the
power supply. Table 157 on page 251 shows the FRU names for the FID numbers in Figure 79 on page
251. Figure 79 on page 251 shows two drive canisters installed.
a05m0253
82
85
EA
Figure 79: Drive enclosure FRU locations in a rack
Table 157: FID numbers and FRU names
FID number
FRU name
Procedure location page
82
Rack power supply
“FID 82: Power supply” on page 252
85
Rack drive canister
“FID 85: Drive canister” on page 252
EA
Rack cables FRU kit
“FID EA: Cables FRU kit” on page 255
©
Copyright IBM Corp. 2010, 2018
251