806f000f-220103ff
The System
[ComputerSystemElementName]
encountered firmware error -
unrecoverable boot device failure.
(ABR Status)
Explanation:
This message is for the use case when
an implementation has detected that System Firmware
Error Unrecoverable boot device failure has occurred.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Hard Disk drive
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0770
SNMP Trap ID:
5
Automatically notify Support:
No
User response:
This is a UEFI detected event. The
UEFI(POST) error code for this event can be found in
the logged IMM message text. Please refer to the
UEFI(POST) error code in the "UEFI(POST) error code"
section of the Information Center for the appropriate
user response. Firmware Error : Sys Boot Status :
806f000f-220104ff
The System
[ComputerSystemElementName]has
encountered a motherboard failure.
(ABR Status)
Explanation:
This message is for the use case when
an implementation has detected that a fatal
motherboard failure in the system.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0795
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
This is a UEFI detected event. The
UEFI(POST) error code for this event can be found in
the logged IMM message text. Please refer to the
UEFI(POST) error code in the "UEFI(POST) error code"
section of the Information Center for the appropriate
user response. Firmware Error : Sys Boot Status :
806f000f-220107ff
The System
[ComputerSystemElementName]
encountered firmware error -
unrecoverable keyboard failure. (ABR
Status)
Explanation:
This message is for the use case when
an implementation has detected that System Firmware
Error Unrecoverable Keyboard failure has occurred.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0764
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
This is a UEFI detected event. The
UEFI(POST) error code for this event can be found in
the logged IMM message text. Please refer to the
UEFI(POST) error code in the "UEFI(POST) error code"
section of the Information Center for the appropriate
user response. Firmware Error : Sys Boot Status :
806f000f-22010aff
The System
[ComputerSystemElementName]
encountered firmware error - no video
device detected. (ABR Status)
Explanation:
This message is for the use case when
an implementation has detected that System Firmware
Error No video device detected has occurred.
Internal Event:
No
Severity:
Error
Alert Category:
Critical - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0766
SNMP Trap ID:
50
Automatically notify Support:
No
User response:
This is a UEFI detected event. The
UEFI(POST) error code for this event can be found in
the logged IMM message text. Please refer to the
UEFI(POST) error code in the "UEFI(POST) error code"
section of the Information Center for the appropriate
user response. Firmware Error : Sys Boot Status :
806f000f-22010bff
Firmware BIOS (ROM)
corruption was detected on system
[ComputerSystemElementName] during
POST. (ABR Status)
Explanation:
Firmware BIOS (ROM) corruption was
detected on the system during POST.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Other
Serviceable:
Yes
806f000f-220103ff • 806f000f-22010bff
74
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...