Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Inspect and reseat operator information panel cable
at both ends.
2. Verify that the Baseboard Management Controller
(BMC) is working.
3. Run the test again.
4. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added:
08/29/2012
Reviewed:
08/29/2012
180-901-000 Check-point Panel Test Failed
Explanation:
Check-point Panel Test Failed. Operator
reported incorrect display.
Internal Event:
No
Severity:
Error
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Check the operator information panel cabling for
loose or broken connections at both ends or
damage to the cable.
2. Replace the information panel cable if damage is
present.
3. Run the test again.
4. Replace the operator information panel assembly.
5. Run the test again.
6. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added:
08/29/2012
Reviewed:
08/29/2012
089-000-000 CPU Stress Test Passed
Explanation:
CPU Stress Test Passed.
Internal Event:
No
Severity:
Event
Serviceable:
No
Recoverable:
No
Automatically notify Support:
No
Date Message Added:
07/30/2012
Reviewed:
08/13/2012
089-801-000 CPU Stress Test Aborted
Explanation:
CPU Stress Test Aborted. Internal
Program Error.
Internal Event:
No
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the
latest level.
3. Run the test again.
4. Check system firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component. The
latest level firmware for this component can be
found in reference to this system type at the IBM
Support website: http://www.ibm.com/systems/
support/supportsite.wss/docdisplay?lndocid=MIGR-
4JTS2T&brandind=5000008.
5. Run the test again.
6. If the system has stopped responding, turn off and
restart the system and then run the test again.
7. If failure remains, refer to "Troubleshooting by
symptom" in the system "Installation and Service
Guide" for the next corrective action.
Date Message Added:
07/30/2012
Reviewed:
08/29/2012
089-802-000 CPU Stress Test Aborted
Explanation:
CPU Stress Test Aborted. System
resource unavailability error.
Internal Event:
No
Severity:
Warning
Serviceable:
Yes
Recoverable:
No
Automatically notify Support:
No
User response:
Complete the following steps:
1. Turn off and restart the system.
2. Make sure that the DSA Diagnostic code is at the
latest level.
3. Run the test again.
4. Check system firmware level and upgrade if
necessary. The installed firmware level can be found
in the DSA Diagnostic Event Log within the
Firmware/VPD section for this component.
180-901-000 • 089-802-000
Chapter 3. Diagnostics
199
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...