806f090c-200dffff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 13)
Explanation:
This message is for the use case when
an implementation has detected Memory has been
Throttled.
Internal Event:
No
Severity:
Warning
Alert Category:
System - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0142
SNMP Trap ID:
22
Automatically notify Support:
No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-200effff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 14)
Explanation:
This message is for the use case when
an implementation has detected Memory has been
Throttled.
Internal Event:
No
Severity:
Warning
Alert Category:
System - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0142
SNMP Trap ID:
22
Automatically notify Support:
No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-200fffff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 15)
Explanation:
This message is for the use case when
an implementation has detected Memory has been
Throttled.
Internal Event:
No
Severity:
Warning
Alert Category:
System - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0142
SNMP Trap ID:
22
Automatically notify Support:
No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f090c-2010ffff
[PhysicalMemoryElementName]
on Subsystem [MemoryElementName]
Throttled. (DIMM 16)
Explanation:
This message is for the use case when
an implementation has detected Memory has been
Throttled.
Internal Event:
No
Severity:
Warning
Alert Category:
System - Other
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0142
SNMP Trap ID:
22
Automatically notify Support:
No
User response:
1.
Reseat the DIMM, and then restart the server.
2.
Replace DIMM n. (n = DIMM number)
806f0a07-0301ffff
[ProcessorElementName] is
operating in a Degraded State. (CPU 1)
Explanation:
This message is for the use case when
an implementation has detected a Processor is running
in the Degraded state.
Internal Event:
No
Severity:
Warning
Alert Category:
Warning - CPU
Serviceable:
Yes
CIM Information: Prefix:
PLAT and
ID:
0038
SNMP Trap ID:
42
Automatically notify Support:
No
User response:
1.
Make sure that the fans are operating, that there
are no obstructions to the airflow (front and rear of
the server), that the air baffles are in place and
correctly installed, and that the server cover is
installed and completely closed.
2.
Check the ambient temperature. You must be
operating within the specifications.
3.
Make sure that the heat sink for microprocessor n
is installed correctly.
4.
(Trained technician only) Replace microprocessor
n. (n = microprocessor number)
806f090c-200dffff • 806f0a07-0301ffff
118
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...