![IBM System x iDataPlex dx360 M4 7912 Service Manual Download Page 364](http://html1.mh-extra.com/html/ibm/system-x-idataplex-dx360-m4-7912/system-x-idataplex-dx360-m4-7912_service-manual_3307498364.webp)
–
Product Data
Select this choice to view the system-board identifier, the revision level or
issue date of the firmware, the integrated management module and
diagnostics code, and the version and date.
This choice is on the full Setup utility menu only.
v
System Settings
Select this choice to view or change the server component settings.
–
Processors
Select this choice to view or change the processor settings.
–
Memory
Select this choice to view or change the memory settings.
–
Devices and I/O Ports
Select this choice to view or change assignments for devices and input/output
(I/O) ports. You can configure the serial ports, configure remote console
redirection, enable or disable integrated Ethernet controllers, the SAS/SATA
controllers, SATA optical drive channels, PCI slots, and video controller. If you
disable a device, it cannot be configured, and the operating system will not be
able to detect it (this is equivalent to disconnecting the device).
–
Power
Select this choice to view or change power capping to control consumption,
processors, and performance states.
–
Operating Modes
Select this choice to view or change the operating profile (performance and
power utilization).
–
Legacy Support
Select this choice to view or set legacy support.
-
Force Legacy Video on Boot
Select this choice to force INT video support, if the operating system does
not support UEFI video output standards.
-
Rehook INT 19h
Select this choice to enable or disable devices from taking control of the
boot process. The default is
Disable
.
-
Legacy Thunk Support
Select this choice to enable or disable UEFI to interact with PCI mass
storage devices that are non-UEFI compliant.
–
Integrated Management Module II
Select this choice to view or change the settings for the integrated
management module.
-
POST Watchdog Timer
Select this choice to view or enable the POST watchdog timer.
-
POST Watchdog Timer Value
Select this choice to view or set the POST loader watchdog timer value.
-
Reboot System on NMI
Enable or disable restarting the system whenever a nonmaskable interrupt
(NMI) occurs.
Disabled
is the default.
-
Commands on USB Interface Preference
Select this choice to enable or disable the Ethernet over USB interface on
IMM2.
346
System x iDataPlex dx360 M4 Types 7912 and 7913: Problem Determination and Service Guide
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...