![IBM System x iDataPlex dx360 M4 7912 Service Manual Download Page 149](http://html1.mh-extra.com/html/ibm/system-x-idataplex-dx360-m4-7912/system-x-idataplex-dx360-m4-7912_service-manual_3307498149.webp)
Automatically notify Support:
No
User response:
No action; information only.
8103010e-2581ffff
Sensor [SensorElementName]
has deasserted. (Memory Resized)
Explanation:
This message is for the use case when
an implementation has detected a Sensor has
deasserted.
Internal Event:
No
Severity:
Info
Alert Category:
System - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0509
SNMP Trap ID:
Automatically notify Support:
No
User response:
No action; information only.
8107010f-2201ffff
Sensor [SensorElementName]
has deasserted the transition from
normal to non-critical state. (GPT
Status)
Explanation:
This message is for the use case when
an implementation has detected that a Sensor has
deasserted a transition to non-critical from normal.
Internal Event:
No
Severity:
Info
Alert Category:
Warning - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0521
SNMP Trap ID:
60
Automatically notify Support:
No
User response:
No action; information only.
8107010f-2582ffff
Sensor [SensorElementName]
has deasserted the transition from
normal to non-critical state. (I/O
Resources)
Explanation:
This message is for the use case when
an implementation has detected that a Sensor has
deasserted a transition to non-critical from normal.
Internal Event:
No
Severity:
Info
Alert Category:
Warning - Other
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0521
SNMP Trap ID:
60
Automatically notify Support:
No
User response:
No action; information only.
81070201-0301ffff
Sensor [SensorElementName]
has transitioned to a less severe state
from critical. (CPU 1 OverTemp)
Explanation:
This message is for the use case when
an implementation has detected a Sensor transition to
less severe from critical.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Temperature
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0523
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
No action; information only.
81070201-0302ffff
Sensor [SensorElementName]
has transitioned to a less severe state
from critical. (CPU 2 OverTemp)
Explanation:
This message is for the use case when
an implementation has detected a Sensor transition to
less severe from critical.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Temperature
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0523
SNMP Trap ID:
0
Automatically notify Support:
No
User response:
No action; information only.
81070202-0701ffff
Sensor [SensorElementName]
has transitioned to a less severe state
from critical. (SysBrd Vol Fault)
Explanation:
This message is for the use case when
an implementation has detected a Sensor transition to
less severe from critical.
Internal Event:
No
Severity:
Info
Alert Category:
Critical - Voltage
Serviceable:
No
CIM Information: Prefix:
PLAT and
ID:
0523
8103010e-2581ffff • 81070202-0701ffff
Chapter 3. Diagnostics
131
Summary of Contents for System x iDataPlex dx360 M4 7912
Page 1: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 2: ......
Page 3: ...System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 22: ...4 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 278: ...260 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 292: ...274 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 392: ...374 System x iDataPlex dx360 M4 Types 7912 and 7913 Problem Determination and Service Guide...
Page 399: ......
Page 400: ...Part Number 46W8218 Printed in USA 1P P N 46W8218...