SDIOP-PIP1:
For
use
by
authorized
service
providers.
Use
this
procedure
to
perform
an
IPL
to
dedicated
service
tool
(DST)
to
determine
if
the
same
reference
code
occurs.
If
a
new
reference
code
occurs,
more
analysis
may
be
possible
with
the
new
reference
code.
If
the
same
reference
code
occurs,
you
are
instructed
to
exchange
the
failing
items.
1.
If
the
system
has
logical
partitions,
perform
this
procedure
from
the
logical
partition
that
reported
the
problem.
To
determine
if
the
system
has
logical
partitions,
go
to
before
continuing
with
this
procedure.
2.
Was
the
IPL
performed
from
disk
(Type
A
or
Type
B)?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
step
5
(See
page
3.
Perform
the
following:
a.
Ensure
that
the
IPL
media
is
the
correct
version
and
level
that
are
needed
for
the
system
model.
b.
Ensure
that
the
media
is
not
physically
damaged.
c.
Choose
from
the
following
options
to
clean
the
IPL
media:
v
If
it
is
cartridge
type
optical
media
(for
example,
DVD),
do
not
attempt
to
clean
the
media.
v
If
it
is
non-cartridge
type
media
(for
example,
CD-ROM),
wipe
the
disc
in
a
straight
line
from
the
inner
hub
to
the
outer
rim.
Use
a
soft,
lint-free
cloth
or
lens
tissue.
Always
handle
the
disc
by
the
edges
to
avoid
finger
prints.
v
If
it
is
tape,
clean
the
recording
head
in
the
tape
unit.
Use
the
correct
IBM
Cleaning
Cartridge
Kit.
4.
Perform
a
Type
D
IPL
in
Manual
mode.
Does
a
system
reference
code
(SRC)
appear
on
the
control
panel?
v
Yes
:
Is
the
SRC
the
same
one
that
sent
you
to
this
procedure?
–
Yes
:
You
cannot
continue
isolating
the
problem.
Use
the
original
SRC
and
exchange
the
failing
items,
starting
with
the
highest
probable
cause
of
failure
(see
the
failing
item
list
for
this
reference
code
in
the
If
the
failing
item
list
contains
FI
codes,
see
to
help
determine
part
numbers
and
location
in
the
system.
This
ends
the
procedure.
–
No
:
A
different
SRC
occurred.
Use
the
new
SRC
to
correct
the
problem
(see
This
ends
the
procedure.
v
No
:
Go
to
step
8
(See
page
Analyze
hardware
problems
187