Table
4.
Configuration
ID
ID
Model
80
FC
5065,
FC
5066
81
FC
5074,
FC
5079,
FC
8079
(002),
FC
8093-002
82
FC
9079
(on
Model
840),
FC
8079
(001)
83
FC
9074
(on
Model
830)
84
FC
5078,
FC
0578
90
FC
5075
Use
the
arrow
keys
to
increment
/
decrement
to
correct
Configuration
ID.
(07xx
will
be
displayed
where
xx
is
the
Configuration
ID).
Press
Enter
.
(07xx
00
will
be
displayed.)
e.
After
a
few
seconds
the
display
on
the
addressed
non-system
unit
will
stop
blinking
and
return
to
displaying
the
frame
address.
On
a
system
unit,
the
display
will
not
show
the
series
of
bring
up
SRCs
on
the
panel.
After
going
through
function
07A9
from
the
panel
exit
back
to
function
01
manually,
the
tower
ID
is
updated.
f.
If
this
operation
was
done
on
a
non-system
unit,
use
the
arrow
keys
to
increment/decrement
to
display
07**
.
Press
Enter
to
display
07.
You
can
now
scroll
to
any
function
needed.
19.
Power
on
the
system.
Does
the
SRC
1xxx
840D,
840E,
or
840F
occur
on
the
panel?
v
Yes
:
Continue
with
the
next
step.
v
No
:
This
ends
the
procedure.
20.
Perform
the
following:
a.
Power
off
the
system.
b.
Exchange
the
SPCN
card
in
the
system
unit
(see
symbolic
FRU
This
ends
the
procedure.
21.
Is
the
SRC
1xxx
8430
or
1xxx
8440?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Perform
the
following:
a.
Power
off
the
system.
b.
Connect
the
V/S
COMM
cable
(see
for
the
part
number).
c.
Power
on
the
system.
Does
the
same
SRC
appear
on
the
control
panel?
–
No
:
Continue
with
the
next
step.
–
Yes
:
Go
to
the
next
FRU
on
the
list.
This
ends
the
procedure.
22.
Is
the
SRC
1xxx
8431
or
1xxx
8441?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Perform
the
following:
a.
Power
off
the
system.
b.
Disconnect
the
V/S
COMM
cable
(see
for
the
part
number).
c.
Power
on
the
system.
Does
the
same
SRC
appear
on
the
control
panel?
–
No
:
This
ends
the
procedure.
–
Yes
:
Go
to
the
next
FRU
on
the
list.
This
ends
the
procedure.
Instructions
for
Models
800,
810,
825,
870,
and
890
346
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation