Failing
item
code
Description/Action
FI01130
For
Models
270
and
820:
FI01130
indicates
that
the
disk
drive
and
logic
card
is
the
failing
item.
Find
the
disk
unit
type
number
in
the
to
determine
the
part
number.
For
Models
830,
840,
SB2,
and
SB3:
This
failing
item
is
in
a
migrated
tower.
See
the
failing
item
table
for
this
failing
item
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
FI01131
This
failing
item
is
in
a
migrated
tower.
See
the
failing
item
table
for
this
failing
item
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
FI01132
This
failing
item
is
in
a
migrated
tower.
SSee
the
failing
item
table
for
this
failing
item
in
the
manual
on
the
V5R1
Supplemental
Manuals
web
site
.
FI01140
FI01140
indicates
that
the
I/O
(SCSI)
bus
cable
is
the
failing
item.
Perform
the
following:
1.
Are
there
external
devices
attached?
v
No
:
Continue
with
the
next
step.
v
Yes
:
For
SCSI
attached
external
devices,
see
For
Fibre
Channel
attached
external
devices,
see
2.
Find
the
IOP
address
(see
3.
To
determine
the
location
of
the
I/O
processor
card,
see
4.
Exchange
the
failing
item
associated
with
the
IOP
address.
Note:
Any
of
the
SCSI
cables
or
backplanes
between
the
IOA
and
the
device
could
be
the
failing
item.
See
FI01141
FI01141
indicates
that
a
loss
of
power
to
an
IOP,
to
an
internal
device,
or
to
an
external
device
may
have
occurred.
1.
Are
0000
xxxx,
1xxx
xxxx,
or
A6xx
698x
SRCs
displayed
on
the
control
panel?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
and
use
the
SRC
displayed
on
the
control
panel.
2.
Did
the
SRC
that
directed
you
to
this
FI
code
involve
an
externally
attached
device
or
an
IOP
with
an
externally
attached
device?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Verify
that
there
is
no
obvious
problem
with
power
to
the
device.
If
you
suspect
a
power
problem
with
the
device,
go
to
the
service
information
for
that
external
device.
3.
The
power
supply
cables
or
connections
to
internal
disk
units,
tape
units,
diskette
units,
or
optical
storage
units
may
be
the
failing
item.
v
For
cable
information,
see
v
For
part
numbers,
see
the
FI01201
FI01201,
FI01202,
and
FI01203
indicates
that
the
disk
drive
and
logic
card
is
the
failing
item.
Find
the
disk
unit
type
number
in
the
to
determine
the
part
number.
FI01202
See
FI01201
(See
page
FI01203
See
FI01201
(See
page
Analyze
hardware
problems
267