1.
Check
the
position
of
the
on/off
switch
on
the
bulk
power
regulator
(BPR)
referenced
by
the
error
code.
Is
the
switch
in
the
ON
position
(to
the
left)?
v
Yes:
Continue
with
the
next
step.
v
No:
Set
the
switch
to
the
ON
position,
press
the
(white)
Service
Complete
button,
and
go
to
This
ends
the
procedure.
2.
Exchange
the
following
field
replaceable
units
(FRUs)
one
at
a
time:
v
Bulk
power
regulator
(BPR)
referenced
by
the
error
code
that
sent
you
to
this
procedure.
See
symbolic
FRU
v
Bulk
power
controller
(BPC)
on
the
side
referenced
by
the
error
code
that
sent
you
to
this
procedure.
See
symbolic
FRU
v
Bulk
power
enclosure
(BPE)
on
the
side
referenced
by
the
error
code
that
sent
you
to
this
procedure.
See
for
the
part
number
and
a
link
to
the
remove
and
replace
procedure.
After
each
FRU
is
exchanged,
is
the
error
code
that
sent
you
to
this
procedure
still
reported?
v
Yes:
Exchange
the
next
FRU
on
the
list.
If
all
of
the
FRUs
have
been
exchanged,
then
call
your
next
level
of
support.
This
ends
the
procedure.
v
No:
Go
to
This
ends
the
procedure.
MAPPWR-3:
An
open
room
EPO
switch
has
been
detected
from
one
side
For
use
by
authorized
service
providers.
Note:
Read
the
Danger
and
caution
notices
in
the
introduction
before
performing
this
procedure.
1.
Ensure
the
following
for
the
Model
870
and
890
system
unit:
v
If
the
room
EPO
cable
is
not
installed:
Make
sure
that
the
room
EPO
BYPASS
switch
on
the
bottom
of
the
EPO
panel
is
to
the
left
(blocking
cable
installation).
v
If
the
room
EPO
cable
is
installed:
Check
to
ensure
that
the
customer’s
room
EPO
switch
is
not
tripped,
and
the
cable
is
connected
and
seated
correctly.
2.
Check
the
Unit
Emergency
Power
Off
(UEPO)
card
assembly.
Is
a
customer
room
EPO
cable
plugged
into
the
UEPO
panel?
v
Yes:
Continue
with
the
next
step.
v
No:
Go
to
step
4
(See
page
.
3.
Perform
the
following:
a.
Set
the
UEPO
switch
on
both
bulk
power
controllers
(BPCs)
to
the
BYPASS
position.
b.
Unplug
the
customer
room
EPO
cable.
c.
Set
the
internal
toggle
switch
on
the
bottom
of
the
UEPO
panel
to
EPO
BYPASS
position.
See
reference
number
6,
in
the
Models
870
and
890
-
Unit
Emergency
Power
Off
(UEPO)
card
assembly
remove
and
replace
procedure.
d.
Set
the
UEPO
switch
on
both
BPCs
back
to
the
NORMAL
position.
e.
Press
the
(white)
Service
complete
button.
Is
error
code
1011
00AC,
101A
FDB6,
or
101B
FDB6
generated?
v
Yes:
Continue
with
the
next
step.
v
No:
Go
to
step
5
(See
page
.
4.
Exchange
the
following
field
replaceable
units
(FRUs)
one
at
a
time:
v
UEPO
card
assembly.
See
for
the
part
number
and
a
link
to
the
remove
and
replace
procedure.
368
iSeries:
iSeries
Server
270,
800,
810,
820,
825,
830,
840,
870,
890,
SB2,
and
SB3
Hardware
Problem
Analysis
and
Isolation