5.
Is
the
resource
for
one
of
the
B600
5311
SRCs
the
load
source
device
and
are
all
of
the
other
B600
5311
entries
for
resources
which
are
non-configured
disk
units?
Note:
To
determine
if
a
disk
unit
is
a
non-configured
disk
unit,
refer
to
the
″
Work
with
disk
unit
options
″
section
in
the
″
DST
options
″
section
of
the
″
DST
chapter
″
in
the
iSeries
Service
Functions
information.
v
Yes
:
Is
the
partition
that
is
reporting
the
error
the
Primary
partition?
–
Yes
:
Continue
with
the
next
step.
–
No
:
Go
to
step
7
(See
page
v
No
:
Go
to
step
8
(See
page
6.
Was
the
load
source
disk
unit
migrated
from
another
partition
within
the
same
system?
v
Yes
:
Is
this
load
source
device
intended
to
be
the
load
source
for
the
Primary
partition?
–
Yes
:
To
accept
the
load
source
disk
unit:
Go
to
SST/DST
in
the
current
partition
and
select
Work
with
system
partitions
—>
Recover
configuration
data
—>
Accept
load
source
disk
unit
This
ends
the
procedure.
–
No
:
Power
off
the
system.
Return
the
original
load
source
disk
to
the
Primary
partition
and
perform
a
system
IPL.
This
ends
the
procedure.
v
No
:
The
load
source
disk
unit
has
not
changed.
Contact
your
next
level
of
support.
This
ends
the
procedure.
7.
The
reporting
partition
is
a
secondary
partition.
Since
the
last
IPL
of
the
reporting
partition,
have
one
of
the
following
occurred:
v
Has
the
Primary
partition
time/date
been
moved
backward
to
a
time/date
earlier
than
the
previous
setting?
v
Has
the
system
serial
number
been
changed?
v
Was
the
load
source
disk
unit
in
this
secondary
partition,
replaced
intentionally
with
a
load
source
from
another
system
or
another
partition
from
the
same
system?
v
Yes
:
To
accept
the
load
source
disk
unit:
Go
to
SST/DST
in
the
current
partition
and
select
Work
with
system
partitions
—>
Recover
configuration
data
—>
Accept
load
source
disk
unit
This
ends
the
procedure.
v
No
:
Contact
your
next
level
of
support.
This
ends
the
procedure.
8.
One
or
more
B600
5311
SRCs
have
been
logged
in
the
same
partition.
Do
all
of
the
B600
5311
errors
have
a
resource
which
is
a
non-configured
disk
unit
in
the
partition?
Note:
To
determine
if
a
disk
unit
is
a
non-configured
disk
unit,
refer
to
the
″
Work
with
disk
unit
options
″
section
in
the
″
DST
options
″
section
of
the
″
DST
chapter
″
in
the
iSeries
Service
Functions
information.
v
Yes
:
Continue
with
the
next
step.
v
No
:
None
of
the
conditions
in
this
procedure
have
been
met,
call
your
next
level
of
support.
This
ends
the
procedure.
9.
Were
any
disk
unit
resources
associated
with
the
B600
5311
SRCs
added
to
the
partition,
since
the
last
IPL
of
this
partition?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Perform
the
following
to
clear
non-configured
disk
unit
configuration
data:
a.
Go
to
SST/DST
in
the
partition
and
select
Work
with
system
partitions
—>
Recover
configuration
data
—>
Clear
non-configured
disk
unit
configuration
data
.
b.
Select
each
unit
in
the
list
which
is
new
to
the
system
and
press
Enter
.
c.
Continue
the
system
IPL.
This
ends
the
procedure.
Analyze
hardware
problems
145