A
power
supply
is
reporting
a
load
fault.
Read
the
for
important
safety
information
before
servicing
the
system.
1.
If
the
system
has
logical
partitions,
perform
this
procedure
only
from
the
Primary
partition’s
console
and
the
system
control
panel.
To
determine
if
the
system
has
logical
partitions,
go
to
before
continuing
with
this
procedure.
2.
Perform
the
following:
a.
Power
off
the
system.
b.
Remove
and
label
all
cards
except
Processors
and
M06
installed
in
the
Processor
backplane
area.
See
Note:
Remove
the
internal
HSL
cable
(SIGC73)
that
connects
from
location
-C08
to
backplane
-MB1
before
sliding
out
the
processor
tray.
c.
Reconnect
the
ac
power
cable
to
the
unit
you
are
working
on.
d.
Power
on
the
system.
Does
a
power
reference
code
occur?
v
Yes
:
Continue
with
the
next
step.
v
No
:
Go
to
step
9
(See
page
3.
Perform
the
following:
a.
Power
off
the
system.
b.
Remove
power
supply
PP2.
c.
Power
on
the
system.
Does
a
power
reference
code
occur?
v
No
:
Continue
with
the
next
step.
v
Yes
:
Go
to
step
5
(See
page
4.
Perform
the
following:
a.
Power
off
the
system.
b.
Reconnect
power
supply
PP2
that
you
removed
in
step
3
(See
page
c.
Power
on
the
system.
Does
a
power
reference
code
occur?
v
No
:
Go
to
This
ends
the
procedure.
v
Yes
:
Exchange
the
power
supply
PP2
reconnected
in
this
step.
This
ends
the
procedure.
5.
Perform
the
following:
a.
Power
off
the
system.
b.
Remove
power
supply
PP1.
c.
Reconnect
power
supply
PP2.
d.
Power
on
the
system.
Does
a
power
reference
code
occur?
v
Yes
:
Is
the
SRC
1xxx-2602
or
2604?
–
No
:
Continue
with
the
next
step.
–
Yes
:
Go
to
step
8
(See
page
v
No
:
Exchange
the
power
supply
PP1.
This
ends
the
procedure.
6.
Perform
the
following:
a.
Reconnect
power
supply
PP1.
Analyze
hardware
problems
167