Troubleshooting Charts
Table 4. Expansion Unit Troubleshooting Chart
Problem Indicator
Component
Possible Cause
Possible Solutions
Unable to access
drives on one or
both SCSI buses
Drives and SCSI bus
Incorrect SCSI ID
settings
Make sure SCSI cables are undamaged and
properly connected. Check the drive SCSI ID
settings. If drives are daisy chained to the
same SCSI bus, Option switches 1 and 2 must
be set to different SCSI ID settings.
ESM board failure
Have the ESM board replaced (service
technician only).
SCSI bus
Cable too long
If the external SCSI controller is SE (check
LEDs), make sure the cable length is
appropriate.
Random errors
Subsystem
Midplane failure
Have the midplane replaced (service
technician only).
Note: If you cannot find the problem in the troubleshooting charts, test the entire system. See your
server documentation for more detailed information on testing and diagnostic tools.
If you already have run the server test program, or if running the test does not reveal the
problem, have the system serviced. (See Chapter 6, “Getting Help, Service, and Information”
on page 63.)
62
IBM Netfinity EXP15 Installation and User's Handbook
Summary of Contents for EXP15
Page 1: ...IBM Netfinity EXP15 Installation and User s Handbook...
Page 2: ......
Page 3: ...IBM Netfinity EXP15 Installation and User s Handbook IBM...
Page 8: ...vi IBM Netfinity EXP15 Installation and User s Handbook...
Page 13: ...Safety Information xi...
Page 19: ...Safety Information xvii...
Page 22: ...xx IBM Netfinity EXP15 Installation and User s Handbook...
Page 26: ...Welcome and Thank You xxiv IBM Netfinity EXP15 Installation and User s Handbook...
Page 118: ...92 IBM Netfinity EXP15 Installation and User s Handbook...
Page 124: ...IBM Part Number 24L7940 Printed in U S A September 1998 24L794...