6-68
Wiring diagram
16. MALFUNCTION OF ARM REGENERATION SOLENOID
Fault code : HCESPN 170, FMI 4 or 6
Before carrying out below procedure, check all the related connectors are properly inserted.
INSPECTION PROCEDURE
侍
1)
CN-135
NO.26
2
1
ARM REGENERATION SOLENOID
FUSE
CN-52
1
MCU
380L6MS05
余
SPEC :
Starting switch ON : 24
佳
2V
See TEST 20
SPEC : 15~35
̫
Check voltage
between CN-52
(1)-GND
Check resistance
between arm
regen solenoid
NO
YES
YES
NO
YES
NO
Cause
Remedy
Defective MCU
Short circuit or
poor connection
between CN-52
(1)-CN-135 (1)
Defective
solenoid valve
Open circuit
between CN-135
(2)-Fuse No. 26
Replace
Replace or repair
Replace
Replace or repair
Check voltage
between CN-135(2)
- GND
SPEC :
Starting switch ON : 20~30V