6-26
3. BATTERY CHARGING WARNING LAMP LIGHTS UP (Starting switch : ON)
余
Before disconnecting the connector, always turn the starting switch OFF.
余
Before carrying out below procedure, check all the related connectors are properly inserted.
余
After checking, insert the disconnected connectors again immediately unless otherwise specified.
Cause
Remedy
Defective MCU
Disconnection in
wiring harness or
poor contact
between CN-52
(27)-CN-2 (13)
Disconnection in
wiring harness or
poor contact
between CN-2 (13)
alternator terminal
"L"
Defective alternator
Replace
Repair or replace
(after clean)
Repair or replace
(after clean)
Replace
YES
YES
YES
NO
NO
NO
MCU
27
CN-52
13
CN-2
ALTERNATOR
CN-74
B+
L
G
~
3
U
Engine : Running
Voltage : 20~32V
Check voltage
between alternator
terminal "L" and
chassis
Check voltage
between CN-2
(13) and chassis
Check voltage
between CN-52
(27) and chassis
300L6ES03
Voltage : 20~32V
Voltage : 20~32V
YES
NO
20~32V
0V
Check voltage