6-24
GROUP 3 ELECTRICAL SYSTEM
1. WHEN STARTING SWITCH IS TURNED ON, MONITOR PANEL DISPLAY DOES NOT APPEAR
余
Before disconnecting the connector, always turn the starting switch OFF.
余
Before carrying out below procedure, check all the related connectors are properly inserted and
short of fuse No. 8, 14.
余
After checking, insert the disconnected connectors again immediately unless otherwise specified.
YES
YES
NO
NO
Check voltage
between
CN-56A (2)
and (3)
Check voltage
between CN-5
(9) and (10)
CLUSTER
BATT (24V)
GND
POWER IG (24V)
1
2
3
CN-56A
11
10
9
CN-5
NO.8
FUSE
NO.14
FUSE
Starting switch : ON
Voltage : 20~32V
Cause
Remedy
Defective cluster
Disconnection in
wiring harness or
poor contact
between
CN-5-CN-56A
Disconnection in
wiring harness or
poor contact
between CN-5 (9)
-GND or fuse No.
8, 14
Replace
Repair or replace
(after clean)
Repair or replace
(after clean)
380L6ES01
Starting switch : ON
Voltage : 20~32V
YES
NO
20~32V
0V
Check voltage