5-35
侍#
Some fault codes are not applied to this machine.
Fault code
J1939 SPN
J1939 FMI
Reason
Effect (only when fault code is active)
1961
2791
0
EGR valve control circuit calculated over
temperature - Data valid but above normal
operational range - Least severe level.
High EGR valve driver temperature has been
detected.
Possible reduced engine performance.
1962
641
0
VGT Actuator dr iver over temperature
(calculated) - Data valid but above normal
operating range - Least severe level.
High internal VGT actuator temperature has
been detected.
None on performance.
1974
101
16
Crankcase pressure - Data valid but above
normal operating range - Moderately severe
level. The crankcase breather filter requires
maintenance.
None on performance.
1993
4795
31
Aftertreatment diesel particulate filter missing -
Condition exists. The aftertreatment diesel
particulate filter in the exhaust system is not
present.
Possible reduced engine performance.
2182
1072
3
Engine brake actuator driver 1 circuit - Voltage
above normal, or shorted to high source. High
voltage or an open circuit detected at the
engine brake solenoid number 1 signal circuit.
Possible reduced engine braking performance.
2183
1072
4
Engine brake actuator driver 1 circuit - Voltage
below normal, or shorted to low source. Low
voltage detected at the engine brake solenoid
number 1 signal circuit.
Possible reduced engine braking performance.
2185
3512
3
Sensor supply 4 circuit - Voltage above normal,
or shor ted to high source. High voltage
detected at 5 VDC sensor supply circuit to the
accelerator pedal position sensor.
Engine will only idle.
2186
3512
4
Sensor supply 4 circuit - Voltage below normal,
or shorted to low source. Low voltage detected
at 5 VDC sensor supply circuit to the
accelerator pedal position sensor.
Engine will only idle.
2198
641
11
VGT Actuator driver circuit - Root cause not
known.
Intermittent communication between the smart
VGT controller and the ECM has been
detected. The VGT controller is not interpreting
the J1939 message from the ECM correctly.
Possible reduced engine performance.
2265
1075
3
Electric lift pump for engine fuel supply circuit -
Voltage above normal, or shorted to high
source. High voltage or an open circuit detected
at the fuel lift pump signal circuit.
Engine may not start or may be difficult to start.
2266
1075
4
Electric lift pump for engine fuel supply circuit -
Voltage above normal, or shorted to high
source. High voltage or an open circuit detected
at the fuel lift pump signal circuit.